Energy Audit of the Footwear Factory Administration Building Using the Energy Consumption Intensity Analysis (IKE) Method
DOI:
https://doi.org/10.70609/gtech.v9i1.5880Keywords:
Energy audit, Energy efficiency, ISO 5000, Refrigeration, Consumption Intensity AnalysisAbstract
This study aims to enhance energy efficiency in the administrative buildings of PT. XXX's footwear factory through an energy audit. Improving energy efficiency in cooling and refrigeration systems can significantly reduce energy-related emissions due to high electricity consumption. The research method involves an energy audit in accordance with ISO 50001:2018 standards, which includes collecting historical electricity consumption data, calculating and analyze of the energy consumption intensity (IKE) and analyzing energy-saving opportunities. The analysis results indicate that the Neki A Office Marketing Building and the Bottom Office Building with an average IKE value of 17.08. The criteria building is a bit wasteful. Regarding to the analysis the significant use of electricity in every building is Air conditioning. So, the opportunity to reduce electricity and saving energy has three potentials. However, the significant impact and appropriate to implement common issue is retrofit air conditioning to inverter type. This study concludes that the implementation of energy efficiency measures can result in significant savings in electricity consumption.
References
Abela, A., Hamilton, L., Hitchin, R., Lewry, A., & Pout, C. (2016). Study on Energy Use by Air-Conditioning: Final Report BRE Client Report for the Department of Energy & Climate Change, HPR218-1001-June 2016 Contents. www.nationalarchives.gov.uk/doc/open-government-licence/
Almogbel, A., Alkasmoul, F., Aldawsari, Z., Alsulami, J., & Alsuwailem, A. (2020). Comparison of energy consumption between non-inverter and inverter-type air conditioner in Saudi Arabia. Energy Transitions, 4(2), 191–197. https://doi.org/10.1007/s41825-020-00033-y
Al-Qawasmi, A. R., & Tlili, I. (2018). Energy Efficiency Audit Based on Wireless Sensor and Actor Networks: Air-Conditioning Investigation. Journal of Engineering (United Kingdom), 2018. https://doi.org/10.1155/2018/3640821
Andargie, M. S., & Azar, E. (2019). An applied framework to evaluate the impact of indoor office environmental factors on occupants’ comfort and working conditions. Sustainable Cities and Society, 46, 101447. https://doi.org/10.1016/j.scs.2019.101447
Duggal, B., & Singh, D. P. (2016). Energy Audit of Individual Air Conditioners: A Case Study. IEEE.
Guangul, F. M., & Kandothillath, F. J. (2019). Energy Auditing of HVAC Systems for the Enhancement of Efficiency and Sustainability in Oman: A Case Study of Energy Consumption at Middle East College. https://ssrn.com/abstract=4613970
Hu, S., Yan, D., Guo, S., Cui, Y., & Dong, B. (2017). A survey on energy consumption and energy usage behavior of households and residential building in urban China. Energy and Buildings, 148, 366–378. https://doi.org/10.1016/j.enbuild.2017.03.064
International Organization for Standardization. (2011). ISO 50001 Energy Management Systems-Requirements With Guidance for Use ISO 50001:2011.
Jiang, F., Ma, J., Li, Z., & Ding, Y. (2022). Prediction of energy use intensity of urban buildings using the semi-supervised deep learning model. Energy, 249, 123631. https://doi.org/10.1016/j.energy.2022.123631
Kartini, P. (2017). Analisis Statistik Konsumsi Energi Listrik Pada Bangunan Gedung Yayasan Widya Dharma Pontianak (Vol. 9, Issue 2).
Kementrian Energi dan Sumber Daya Mineral. (2012). Peraturan Menteri Energi dan Sumber Daya Mineral Republik Indonesia Nomor 14 Tahun 2012 Tentang Manajemen Energi.
Latif, M. H., Anis, M., Mahmood, T., & Khalid, W. (2019). Energy Audit, Retrofitting and Solarization in Educational Institutes of Pakistan: An Effective Approach towards Energy Conservation.
Li, H., & Tang, K. (2022). A comprehensive study of drop-in alternative mixtures for R134a in a mobile air-conditioning system. Applied Thermal Engineering, 203, 117914. https://doi.org/10.1016/j.applthermaleng.2021.117914
Narendra Hafid Mustofa, B., Supriyo, & Roihatin, A. (2022). Audit Energi Listrik Gedung A MAN 1 Kota Semarang. Prosiding NCIET, 3.
Pasvorarotkool, S., & Mongkon, S. (2020). Energy Auditing Assessment by ISO 50001 Energy Management Standard in University Building. Spektrum Industry, 18(2). https://doi.org/10.12928/si.v18i1.18396
Rhodes, J. D., Stephens, B., & Webber, M. E. (2011). Using energy audits to investigate the impacts of common air-conditioning design and installation issues on peak power demand and energy consumption in Austin, Texas. Energy and Buildings, 43(11), 3271–3278. https://doi.org/10.1016/j.enbuild.2011.08.032
Roth, J., & Rajagopal, R. (2018). Benchmarking building energy efficiency using quantile regression. Energy, 152, 866–876. https://doi.org/10.1016/j.energy.2018.02.108
Shafyyar Fahmi, G., Suhardi, D., & Widianto. (n.d.). Analisis Audit dan Peningkatan Efisiensi Penggunaan Energi Listrik Pada Sistem Pencahayaan dan Air Conditioning (AC) di Gedung Kantor BPJS Daerah Kota Malang dengan Pendekatan AHP. Seminar Nasional Fortei Regional 7, 335–343.
Sulistyowati, R., Fadholi, A., Adhi, I. T., & Surabaya, T. (n.d.). Optimalisasi Panel Surya Untuk Skala Rumah Tangga. 2022, 11. https://doi.org/10.31284/p.snestik.2022.2554
Sutikno Tole, Purnama Hendril Satrian, Subrata Arsyad Cahya, Pamungkas Anggit, Arsadiando Watra, & Wahono Tri. (2019). Konversi Energi (Manajemen, Prinsip dan Aplikasi).
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Awwalunisa Aliya Kusuma, Heri Sutanto, Muchammad Muchammad

This work is licensed under a Creative Commons Attribution 4.0 International License.








