The Fire Protection Fire Protection Installation in Laboratory Buildings Using Heat Detectors and Smoke Detectors

Authors

  • Gaspar Pereira Maia Pinto Universitas Katolik Indonesia Atma Jaya, Indonesia
  • Djoko Setyanto Universitas Katolik Indonesia Atma Jaya, Indonesia
  • Arka Dwinanda Soewono Universitas Katolik Indonesia Atma Jaya, Indonesia

DOI:

https://doi.org/10.33379/gtech.v8i3.4296

Keywords:

Detector, Fire Protection, Fire

Abstract

The rise of various fire cases needs to be minimized through a fire protection system using equipment that is operated manually or automatically to detect and extinguish fires as early as possible. Changes in temperature and smoke appearing at the location can be parameters for early detection of the fire. This thesis successfully determines the number and point of detectors as well as fire protection installations in laboratory buildings in accordance with Indonesian National Standards (SNI) and Indonesian Regulations, namely the calculation of the number of detectors obtained was 44 units, divided into 22 heat detectors and 22 smoke detectors. On the 1st floor there are 16 detectors installed, 8 smoke detectors and 8 heat detectors, on the 2nd floor 16 units are installed consisting of 8 heat detectors and 8 smoke detectors, while on the 3rd floor there are 12 installed with 6 heat detectors and 6 smoke detectors.

References

--3985-2000, S. (2000). Tata cara perencanaan, pemasangan dan pengujian sistem deteksi dan alarm kebakaran pada bangunan gedung. Jakarta : Badan Standardisasi Nasional., 2000

/PRT/M/2008, P. M. (2008). Persyaratan Teknis Sistem Proteksi Kebakaran pada Bangunan Gedung dan Lingkungan. Indonesia: Menteri Pekerjaan Umum.

Abdullah, A., & Kuntadi, C. (2023). The Influence of the Conformity Level of Fire Alarm Installations, Fire Detectors, and Portable Fire Extinguishers on the Fire Protection System. Dinasti Internasional Jurnal Of Education Management and Sosial Science, 4(4), 517-525.

Association, N. F. (2008). Fire Protecton Handbook 12th ed. In National Fire Protection Association. US. https://www.researchgate.net/publication/40932394_NFPA's_Fire_Protection_Handbook.

Hafidz, M., Hidayat, F., & Sitompul, Z. B. (2012). STUDI SISTEM PENCEGAHAN DAN PENANGGULANGAN KEBAKARAN PADA PABRIK PEMBUATAN PESAWAT TERBANG. Jurnal Teknik Sipil, XI(2), 135-147.

Herlambang, R., & Nurpulaela, L. (2023). Analisis Penggunaan Fire Alarm System Di Bandara Internasional Jawa Barat Kertajati. Jurnal Ilmiah Wahana Pendidikan, IX(15), 570-580.

Irwanto. (2020, Desember). Analisis Instalasi Fire Alarm Sebagai Sistem Proteksi Kebakaran dengan Metode Smoke dan Heat Detector. Seminar Nasional Teknologi Informasi, Komunikasi dan Industri (SNTIKI) 12.

Irwanto, & Anam, A. F. (2023). Analisis Sistem Instalasi Fire Fighting Pada Gedung Control Building SCBD di PT. Jaga Citra Inti Jakarta. Jurnal Teknik Mesin, Industri, Elektro Dan Informatika (JTMEI), II(1), 240-261.

Kowara, Martiana, & Tri. (April 2017). Analisis Sistem Proteksi Kebakaran Sebagai paya Pencegahan Dan Penangulangan Bahaya Kebakaran. Jurnal Manajemen Kesehatan, Yayasan RS Dr Soetomo, 3, 8-9.

Kurniawati, D. (2013). Taktis Memahami Keselamatan dan Kesehatan Kerja Bidang Teknologi Informasi (ed.1 ed.). Surakarta: Surakarta Aksara Sinergi Media.

M, K., B, K., & Sunoto. (2016). Analisa upaya penangulangan kebakaran digedung Bougenville Rumah Sakit Tologerajo Semarang. Jurnal Kesehatan Masyarakat(4), 698-706.

Nugroho, & Purwo, S. (2010). karakteristik Bencana Gagal Teknologi di Indonesia. Jurnal Dialog Penangulangan Bencana, I(1).

PER.02/MEN/1983, P. M. (1983). INSTALASI ALARM KEBAKARAN AUTOMATIK . JAKARTA : Menteri Tenaga Kerja

PER.04/MEN/1980, P. M. (1980). Syarat-Syarat Pemasangan dan Pemeliharaan Alat Pemadam Api Ringan. INDONESIA: MENTERI KETENAGA KERJAAN DAN TRANSMIGRASI.

Qisthi, S. E., & Mutiari, D. (2022). SISTEM PROTEKSI KEBAKARAN PADA BANGUNAN KOMERSIL PASAR JOHAR SELATAN SEMARANG JAWA TENGAH. Seminar Ilmiah Arsitektur III, 632-639.

Ratnayanti, K. R., Hajati, N. L., & Utama, M. I. (2019). Evaluasi Sistem Proteksi Aktif dan Pasif sebagai Upaya Penangulangan Bahaya Kebakaran Pada Gedung X Mall. Jurnal Rekayasa Hijau, 3(1), 1-16.

Reza, M., Sasmito, A., & Sadewo, E. L. (2020). Analisis Sistem Proteksi Kebakaran Gedung Laboratorium Teknik Mesin Fakultas Teknik Universitas Riau. Jurnal Kajian Teknik Mesin, V(1), 22-28.

Rosanti, E., Irawan, S. U., Diannita, R., & Taufik, M. R. (2021). Analisis Model Pemetaan Sistem Proteksi Kebakaran Aktif Di Gedung Asrama Universitas X. The Indonesian Journal of Occupational Safety and Health, 10(2), 240-246.

Ruslan, M., Amin, M. A., & Emidiana. (2021). Perancangan Sistem Fire Alarm Kebakaran Pada Gedung Laboratorium XXX. Jurnal Tekno, 18(2).

Siwi, R. M., & Mardiana. (2018). PENERAPAN SISTEM PROTEKSI AKTIF DAN SARANA PENYELAMATAN JIWA SEBAGAI UPAYA PENCEGAHAN KEBAKARAN. HIGEIA JOURNAL OF PUBLIC HEALTH RESEARCH AND DEVELOPMENT, 2(1), 12-22.

Soehatman, & Ramli. (2010). Manajemen Kebakaran. Jakarta: Dian Rakyat.

Taufiq, M., & Bangsa, I. A. (2023). ANALISIS INSTALASI FIRE ALARM PADA BASEMENT APARTEMENT SEBAGAI SISTEM PROTEKSI KEBAKARAN. Aisyah Journal of Informatics and Electrical Engineering, V(1), 58-66.

Ush Soleh, M. A., Suroto, & Wahyuni, I. (2021). ANALISIS SISTEM PROTEKSI KEBAKARAN AKTIF PADA RUMAH SAKIT GIGI DAN MULUT X DI KOTA BANDUNG. Jurnal Kesehatan Masyarakat, 9(1), 51-57.

Wiharja, U., & Hidayat, M. A. (2014). Perencanaan Sistem Kerja Deteksi Dan Alarm Kebakaran Pada Bangunan Gedung. Jurnal Ilmiah Elektrokrisna, 3(1), 32-37.

Yamauchi, Y., Mammoto, A., Dohi, M., & Ebara, H. (2005). A Calculation Method for Predicting Heat and Smoke Detector's Response. Fire Science and Technolgy, 24(4), 179-210.

Zain, A. (2016). Rancang Bangun Sistem Proteksi Kebakaran Mengunakan Smoke dan Heat Detector. Jurnal Intek, III(1), 36-42.

Zulfiar, M. H., & Gunawan, A. (2018). Evaluasi Sistem Proteksi Kebakaran pada Bangunan Hotel UNY 5 Lantai di Yogyakarta. Semeste Teknika, XXI(1), 65-71.

Published

2024-07-02

How to Cite

The Fire Protection Fire Protection Installation in Laboratory Buildings Using Heat Detectors and Smoke Detectors. (2024). G-Tech: Jurnal Teknologi Terapan, 8(3), 1343-1353. https://doi.org/10.33379/gtech.v8i3.4296